Skip Navigation LinksALVAO 11.1Known issues Skip Navigation Links.


AM Console - AMC does not start - Logged error in event viewer is stating "Faulting module name: ucrtbase.dll"

This article is about product releases

ALVAO Asset Management 11.1 and higher

Symptoms

Log in the event viewer (Windows Logs/Application):

Faulting application name: AMConsole.exe, version: 11.1.***.0, time stamp: 0x6498c55d
Faulting module name: ucrtbase.dll, version: 10.0.22621.608, time stamp: 0xbbf7fb0e
Exception code: 0xc0000409
Fault offset: 0x0009e34b
Faulting process id: 0x0x60EC
Faulting application start time: 0x0x1D9A82D2D361EEA
Faulting application path: C:\Program Files (x86)\ALVAO\Asset Management Console\AMConsole.exe
Faulting module path: C:\WINDOWS\System32\ucrtbase.dll
Report Id: 0753caf8-c01f-49ed-ac31-58e794c5189f
Faulting package full name:
Faulting package-relative application ID:

Cause

The cause is a bug in ALVAO products.

Solution

Fixed in release 11.1.1464 - 11.1/FIX4 (2023-08-03)

Workaround

Delete all folder registry keys named Record# under location Recent Database List at:
Computer\HKEY_CURRENT_USER\Software\ALC\Service Desk\Recent Database List or Počítač\HKEY_CURRENT_USER\Software\ALC\Service Desk\Recent Database List if your system has Czech localization.

Steps to reproduce this behavior

Old connection string to the database is now deprecated (server migration etc).

Attachments

Issue number

T145594ALVAO

 

Did not find what you were looking for? Ask our technical support team.