WA - Administration - Asset Management - Settings - SW product library - does not load the library if "Load from folder" is set
This article is about product releases
ALVAO Asset Management 11.1 and higher
Symptoms
- WA - Administration - Asset Management - Settings - SW product library - "Load from folder" is set
- newer SW library from file is not loaded
Cause
The cause is a bug in ALVAO products.
Solution
Fixed in release 11.2.1134 - 11.2 (2024-04-11)
Workaround
WA - Administration - Asset Management - Settings - SW product library - set "Load from folder" to specific path and specific SWL file (loaded from ALVAO website).
Run following script on the database:
update Server set SwLibDownloadLib=1 where IsAlvaoService=1
Steps to reproduce this behavior
Attachments
Issue number
T150914ALVAO